Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 422
Filtrar
1.
Arq. gastroenterol ; 61: e23088, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1533822

RESUMO

ABSTRACT Background: Inflammatory bowel diseases (IBD) are associated with important changes in nutritional status. Objective: The aim of the study was to compare body fat composition between two anthropometric methods: skinfolds and ultrasonography, in patients with IBD. Methods: Single-center cross-sectional study with IBD patients in remission or active disease. For the agreement analysis between the body fat assessment methods, the Bland Altman method was used. Results: A total of 101 patients with IBD were included, 75 with Crohn's disease and 26 with ulcerative colitis. Approximately 56% of the patients with Crohn's disease and 65.4% of those with ulcerative colitis had a body fat composition above normal levels, with no significant difference between the diseases (P=0.63). The Bland-Altman concordance analysis showed that the methods for assessing the percentage of fat by the adipometer and ultrasound were not in full agreement (P=0.001), despite both presented good correlation (CC 0.961; P=0.000). Conclusion: The analysis of body fat percentage in patients with IBD was different between the skinfolds and ultrasound. Both methods can be used to assess the of body fat percentage of patients with IBD. However, monitoring of body fat sequentially and longitudinally should always be performed using the same method throughout the disease course. Prospective longitudinal studies are warranted to precisely define the role of these two methods of measuring body composition in patients with IBD.


RESUMO Contexto: As doenças inflamatórias intestinais (DII) estão associadas a alterações importantes no estado nutricional. Objetivo: O objetivo do estudo foi comparar a composição da gordura corporal entre dois métodos antropométricos: dobras cutâneas e ultrassonografia, em pacientes com DII. Métodos: Estudo transversal de centro único com pacientes com DII em remissão ou doença ativa. Para a análise de concordância entre os métodos de avaliação da gordura corporal foi utilizado o método de Bland-Altman. Resultados: Foram incluídos 101 pacientes com DII, 75 com doença de Crohn e 26 com colite ulcerativa. Aproximadamente 56% dos pacientes com doença de Crohn e 65,4% daqueles com colite ulcerativa apresentaram composição de gordura corporal acima dos níveis normais, sem diferença significativa entre as doenças (P=0,63). A análise de concordância de Bland-Altman mostrou que os métodos de avaliação do percentual de gordura pelo adipômetro e ultrassonografia não foram totalmente concordantes (P=0,001), apesar de ambos apresentarem boa correlação (CC 0,961; P=0,000). Conclusão: A análise do percentual de gordura corporal em pacientes com DII foi diferente entre as dobras cutâneas e a ultrassonografia. Ambos os métodos podem ser usados para avaliar o percentual de gordura corporal de pacientes com DII. Entretanto, o monitoramento da gordura corporal de forma sequencial e longitudinal deve ser sempre realizado utilizando o mesmo método durante todo o curso da doença. Estudos longitudinais prospectivos são necessários para definir com precisão o papel desses dois métodos de medição da composição corporal em pacientes com DII.

2.
J. vasc. bras ; 23: e20230085, 2024. graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1534796

RESUMO

Resumo O maior ramo da divisão terminal da artéria braquial é a artéria ulnar, que se origina após a fossa cubital. Essa artéria usualmente tem trajeto profundo aos músculos do antebraço anterior e é responsável pela vascularização da musculatura superficial e profunda da região ulnar do antebraço e hipotênar da mão, sendo a principal responsável pela formação do arco palmar superficial após o retináculo dos flexores. Reportamos uma variação anatômica após diagnóstico com ultrassom vascular na qual a artéria ulnar situava-se em posição superficial no antebraço. A ocorrência da artéria ulnar superficial é rara, porém de grande importância para clínicos, cirurgiões e profissionais de enfermagem.


Abstract The largest branch of the terminal division of the brachial artery is the ulnar artery, which arises after the cubital fossa. This artery usually has a deep path in the muscles of the anterior forearm and is responsible for vascularization of the superficial and deep musculature on the ulnar side of the forearm and hypothenar area of the hand. We report an anatomical variant diagnosed by Doppler ultrasound in which the ulnar artery had a superficial position in the forearm. Occurrence of a superficial ulnar artery is rare, but it is an important fact for clinicians, surgeons, and nursing professionals.

3.
BrJP ; 6(4): 374-382, Oct.-Dec. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1527982

RESUMO

ABSTRACT BACKGROUND AND OBJECTIVES: Wound complications and pharmacological pain relief methods used at the skin surgical site after cesarean delivery may result in women's physical and emotional burden. Thus, nonpharmacological treatments must be explored to avoid these complications and side effects on maternal health. The objective of this study was to investigate the effects of Combined Ultrasound and Electric Field Stimulation (CUSEFS) on cicatricial pain and functional capacity in immediate cesarean delivery. METHODS: This study has a randomized clinical trial, double-blind, and placebo-controlled design. Thirty women (25.7±5.0 years) in immediate postpartum were randomly assigned to three groups: Control (CG, n:9), CUSEFS (TG, n:11), and Placebo (PG, n:10). CUSEFS was performed once for 20 minutes. Cicatricial pain (McGill Pain Questionnaire) and functional capacity (Functional Capacity Check) was assessed at baseline, after the intervention, and after 30 minutes. Cohen's (d) and Mixed-design analysis of variance were used to compare groups. RESULTS: Immediately after the intervention, TG showed a decrease in cicatricial pain compared with CG in sensory (d:3.8 to 4.0), affective (d:4.0), and total categories (d:3.9). In functional capacity, TG had less difficulty than CG at walking (d:0.6) and lying down (d:1.1), and PG at rest (d: 0.9). CONCLUSION: CUSEFS might be a resource for managing cicatricial pain and functional capacity in immediate cesarean delivery. Further studies with longer duration and different CUSEFS doses/parameters are required.


RESUMO JUSTIFICATIVA E OBJETIVOS: As complicações na ferida e o uso de métodos farmacológicos de alívio da dor no local cirúrgico após a cesariana podem resultar em sobrecarga física e emocional para a mulher. Assim, tratamentos não farmacológicos devem ser explorados para evitar essas complicações e efeitos adversos à saúde materna. O objetivo deste estudo foi investigar os efeitos da terapia combinada de estimulação elétrica por meio do ultrassom (CUSEFS) na dor cicatricial e na capacidade funcional no pós-parto imediato de cesariana. MÉTODOS: Este estudo possui um desenho de ensaio clínico randomizado, duplo-cego e controlado por placebo. Trinta mulheres (25,7±5,0 anos) em pós-parto imediato de cesariana foram distribuídas aleatoriamente em três grupos: Controle (CG, n:9), CUSEFS (TG:11) e Placebo (PG, n:10). O CUSEFS foi realizado uma vez por 20 minutos. A dor cicatricial (Questionário de Dor McGill) e a capacidade funcional (Functional Capacity Check) foram avaliadas no início, após a intervenção e após 30 minutos. As análises de variância de design misto e Cohen (d) foram usadas para comparar os grupos. RESULTADOS: Imediatamente após a intervenção, o TG apresentou diminuição na dor cicatricial em relação ao CG nas categorias sensorial (d:3,8 a 4,0), afetiva (d:4,0) e total (d:3,9). Na capacidade funcional, o TG apresentou menor dificuldade que o CG na marcha (d:0,6) e deitado (d:1,1), e que o PG em repouso (d:0,9). CONCLUSÃO: O CUSEFS pode ser um recurso para o manejo da dor cicatricial e da capacidade funcional imediatamente após a cesariana. Além disso, são necessários mais estudos com maior duração e diferentes doses/parâmetros de CUSEFS.

4.
Rev. méd. Urug ; 39(4)dic. 2023.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1530275

RESUMO

Objetivo: presentar la utilización de la guía ecográfica en el tórax para realizar biopsias y colocación de drenajes, ya sean pleurales o pericárdicos. Material y método: se realizaron 124 procedimientos ecoguiados en el Instituto del Tórax del Hospital Maciel, desde enero de 2014 hasta agosto de 2022. Resultados: se evaluaron franja etaria, tipo de procedimiento y rentabilidad diagnóstica en los procedimientos ecoguiados. Se realizaron 69 punciones con fines diagnósticos, 48 colocaciones de drenajes pleurales bajo apoyo ecográfico y 7 drenajes pericárdicos. Conclusión: la realización de procedimientos ecoguiados en el tórax es una herramienta diagnóstica y terapéutica segura, con buen rendimiento y mínimas complicaciones.


Objective: To present the use of ultrasound guidance to perform thorax biopsies and place drainages, whether pleural or pericardial. Method: A total of 124 ultrasound-guided procedures were performed at the Thoracic Institute, Maciel Hospital, from January 2014 to August 2022. Results: The results were assessed based on age group, type of procedure, and diagnostic yield in the ultrasound-guided procedures. There were 69 diagnostic punctures, 48 ultrasound-guided pleural drainage placements, and 7 pericardial drainages. Conclusions: The performance of ultrasound-guided thoracic procedures are a safe diagnostic and therapeutic tool with excellent efficacy and minimal complications.


Objetivo: fica no tórax para realização de biópsias e colocação de drenos pleurais ou pericárdicos. Materiais e métodos: foram realizados 124 procedimentos guiados por ultrassom no Instituto del Tórax do Hospital Maciel no período de janeiro de 2014 a agosto de 2022. Resultados: foram avaliadas faixa etária, tipo de procedimento e rentabilidade diagnóstica em procedimentos guiados por ultrassom. Foram realizadas 69 punções para fins diagnósticos, 48 colocações de drenos pleurais sob suporte ultrassonográfico e 7 drenos pericárdicos. Conclusão: a realização de procedimentos guiados por ultrassom no tórax é uma ferramenta diagnóstica e terapêutica segura, com bom desempenho e complicações mínimas.

5.
Rev. bras. ortop ; 58(5): 706-711, Sept.-Oct. 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1529935

RESUMO

Abstract Objective The purpose of the present study is to compare intraoperative blood loss, operating time, laminectomy time, hospital length of stay, and complications in thoracolumbar spinal decompression using ultrasonic bone scalpels (UBSs) with conventional procedures. Methods Forty-two patients who underwent decompressive laminectomy and pedicular screw fusion with a surgical level of 1-5 levels between February 1, 2020, and June 30, 2022, in a single institution were evaluated for eligibility, and 11 were excluded due to a history of spinal surgery (n= 3), spinal tumor (n= 3), and spinal infection (n= 5). A total of 31 patients were randomly divided into the UBS group (n =15) and the conventional group (n =16). Intraoperative blood loss, operating time, laminectomy time, hospital length of stay, and complications were recorded. Results Intraoperative blood loss and laminectomy time were significantly lower in the UBS group (656.0 ± 167.6 ml, 54.5 ± 27.4 minutes, respectively) than in the conventional group (936.9 ± 413.2 ml, 73.4 ± 28.1 minutes, respectively). Overall operation time, hospital length of stay, and complications were all similar between the groups. Conclusion The UBS is a useful instrument for procedures performed near the dura mater or other neural tissue without excessive heat or mechanical injury. This device is recommended for various spinal surgeries in addition to high-speed burrs and Kerrison rongeurs.


Resumo Objetivo O objetivo do presente estudo é comparar perda de sangue intraoperatória, tempo de operação, tempo de laminectomia, tempo de internação hospitalar e complicações na descompressão espinhal torácica utilizando bisturis ósseos ultrassônicos (BOUs) em relação aos procedimentos convencionais. Métodos Quarenta e dois pacientes submetidos a laminectomia descompressiva e fusão pedicular do parafuso com um nível cirúrgico de 1 a 5, entre 1° de fevereiro de 2020 e 30 de junho de 2022 em uma única instituição, foram avaliados para elegibilidade e 11 foram excluídos devido ao histórico de cirurgia espinhal (n= 3), tumor espinhal (n= 3) e infecção espinhal (n= 5). Perda de sangue intraoperatória, tempo de operação, tempo de laminectomia, tempo de internação e complicações foram registradas. Resultados A perda de sangue intraoperatória e o tempo de laminectomia foram significativamente menores no grupo BOU (656,0 ± 167,6 ml, 54,5 ± 27,4 min, respectivamente) do que no grupo convencional (936,9 ± 413,2 ml, 73,4 ± 28,1 min, respectivamente). O tempo de funcionamento total, o tempo de internação e as complicações foram todos semelhantes entre os grupos. Conclusão O bisturi ósseo ultrassônico é um instrumento útil para procedimentos realizados próximos à dura-máter ou outro tecido neural sem calor excessivo ou lesão mecânica. Este dispositivo é recomendado para várias cirurgias de coluna vertebral, juntamente com rebarbas de alta velocidade e pinça Kerrison.


Assuntos
Humanos , Masculino , Feminino , Vértebras Torácicas/diagnóstico por imagem , Descompressão Cirúrgica , Laminectomia
6.
Femina ; 51(7): 390-399, 20230730. ilus
Artigo em Português | LILACS | ID: biblio-1512437

RESUMO

Objetivo: Apresentar a atualização das recomendações do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem, da Sociedade Brasileira de Mastologia e da Federação Brasileira das Associações de Ginecologia e Obstetrícia para o rastreamento do câncer de mama no Brasil. Materiais e Métodos: Foram feitas buscas das evidências científicas publicadas nas bases Medline, EMBASE, Cochrane Library, EBSCO, CINAHL e Lilacs, entre janeiro de 2012 e julho de 2022. As recomendações foram baseadas nessas evidências, mediante consenso da comissão de especialistas das três entidades. Recomendações: O rastreamento mamográfico anual é recomendado para as mulheres de risco habitual entre 40 e 74 anos. Acima de 75 anos, deve ser reservado para as que tenham expectativa de vida maior que sete anos. Mulheres com risco maior que o habitual, entre elas as com mamas densas, com história pessoal de hiperplasia lobular atípica, carcinoma lobular in situ clássico, hiperplasia ductal atípica, tratamento de câncer de mama ou de irradiação no tórax antes dos 30 anos ou, ainda, portadoras de mutação genética ou com forte história familiar, beneficiam-se do rastreamento complementar, sendo consideradas de forma individualizada. A tomossíntese é uma evolução da mamografia e deve ser considerada no rastreamento, sempre que acessível e disponível. (AU)


Objective: To present the update of the recommendations of the Brazilian College of Radiology, the Brazilian Society of Mastology and the Brazilian Federation of Gynecology and Obstetrics Associations for breast cancer screening in Brazil. Materials and Methods: Scientific evidence published in Medline, Embase, Cochrane Library, Ebsco, Cinahl and Lilacs between January 2012 and July 2022 was searched. Recommendations were based on this evidence, by consensus of the expert committee of the three entities. Recommendations: Annual mammographic screening is recommended for women aged between 40 and 74 years old. Above 75 years should be reserved for those with a life expectancy greater than seven years. Women at higher than usual risk, including those with dense breasts, a personal history of atypical lobular hyperplasia, classic lobular carcinoma in situ, atypical ductal hyperplasia, treatment for breast câncer, chest irradiation before age 30, carriers of genetic mutation or with a strong family history, benefit from complementary screening, being considered individually. Tomosynthesis is an evolution of mammography and should be considered in screening, whenever accessible and available. (AU)


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Neoplasias da Mama/prevenção & controle , Programas de Rastreamento/efeitos adversos , Qualidade de Vida , Tórax/efeitos da radiação , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Mamografia , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos de Coortes , Saúde da Mulher , Revisão Sistemática
7.
ABC., imagem cardiovasc ; 36(1): e20230013, abr. 2023. ilus
Artigo em Português | LILACS | ID: biblio-1452547

RESUMO

O choque circulatório é caracterizado por um estado de ineficiência da oferta de oxigênio tecidual e disfunção múltipla de órgãos. Necessita de diagnóstico e terapias rápidas e assertivas para redução de sua alta letalidade. O ecocardiograma já se estabeleceu como método fundamental no manejo do paciente com choque circulatório. Auxilia de forma crucial no diagnóstico etiológico, prognóstico, monitorização hemodinâmica e estimativa volêmica desses pacientes, tendo como potenciais vantagens a portabilidade, ausência de contraste ou radiação, baixo custo e avaliação em tempo real e de forma seriada. Em ambiente de UTI, demonstra alta correlação com formas invasivas (cateter de artéria pulmonar) e minimamente invasivas (termodiluição transpulmonar) de monitorização hemodinâmica. Atualmente, outras técnicas, como ultrassom pulmonar e VExUS score, têm se agregado à avaliação ecocardiográfica, tornando o método mais abrangente e acurado. Essas técnicas acrescentam dados relevantes na estimativa da volemia do paciente crítico, influenciando na decisão probabilística de fluidoresponsividade e agregando informações no raciocínio diagnóstico das causas do choque, otimizando o prognóstico desses pacientes. O point of care ultrasound (POCUS) tem como objetivo tornar mais acessível, ao médico não especialista em radiologia, habilidades para se obter informações a beira leito, por meio do ultrassom, que o ajudem na tomada de decisões. Esse artigo aborda as diversas aplicabilidades do ecocardiograma em pacientes com choque circulatório, incluindo avaliação prognóstica e diagnóstico etiológico por meio dos parâmetros encontrados nas principais causas de choque, além da monitorização hemodinâmica, avaliação de fluido-responsividade e utilização prática do ultrassom pulmonar.(AU)


Circulatory shock is characterized by a state of inefficient tissue oxygen supply and multiple organ dysfunction. Patients with circulatory shock require fast and assertive diagnosis and therapies to reduce its high lethality. Echocardiography has already been established as a fundamental method in managing patients with circulatory shock. It provides crucial assistance in etiological diagnosis, prognosis, hemodynamic monitoring, and volume estimation in these patients; its potential advantages include portability, absence of contrast or radiation, low cost, and real-time serial assessment. In the intensive care unit setting, it demonstrates a high correlation with invasive (pulmonary artery catheter) and minimally invasive (transpulmonary thermodilution) forms of hemodynamic monitoring. Currently, other techniques, such as pulmonary ultrasound and VExUS score, have been added to echocardiographic assessment, making the method more comprehensive and accurate. These techniques add relevant data to blood volume estimation in critical patients, influencing the probabilistic decision of fluid responsiveness and providing additional information in the diagnostic reasoning of the causes of shock, thus optimizing these patients' prognosis. Point of care ultrasound (POCUS) aims to make abilities to obtain information at the bedside more accessible to physicians who are not specialists in radiology, by means of ultrasound, which assists them in decision-making. This article addresses the diverse applications of echocardiography in patients with circulatory shock, including prognostic evaluation and etiological diagnosis by means of the parameters found in the main causes of shock, in addition to hemodynamic monitoring, evaluation of fluid responsiveness, and practical use of pulmonary ultrasound.(AU)


Assuntos
Humanos , Choque Cardiogênico/complicações , Choque Cardiogênico/etiologia , Choque Cardiogênico/diagnóstico por imagem , Função Ventricular/fisiologia , Choque Cardiogênico/prevenção & controle , Volume Sistólico/fisiologia , Ecocardiografia/métodos , Técnicas de Imagem Cardíaca/métodos , Monitorização Hemodinâmica/métodos
8.
Vive (El Alto) ; 6(16): 154-161, abr. 2023.
Artigo em Espanhol | LILACS | ID: biblio-1442266

RESUMO

El Síndrome de Klippel-Trenaunay se constituye en una malformación vascular compleja con una incidencia de 2 a 3 casos por cada 100.000 nacidos vivos, clínicamente presenta una triada clásica: manchas cutáneas en vino de Oporto, venas varicosas de localización atípica e hipertrofia ósea y de tejidos blandos. Se presenta el caso de una paciente femenina de 33 años, sin antecedentes patológicos o quirúrgicos de importancia quien acude a consulta por aumento de volumen de la extremidad derecha, mancha violácea ipsilateral, además de dolor y parestesias. Al examen físico se evidencia aumento longitudinal de miembro inferior derecho, nevus hiperpigmentario en cara lateral de pierna derecha y muslo que se extiende al glúteo ipsilateral además de venas varicosas atípicas. Se practica ecografía Doppler venosa con transductor lineal que reporta incompetencia de vena Safena Mayor y perforantes suprageniculares. Se realizó manejo quirúrgico mediante safenectomía, corrección de deformidad y referencia a dermatología para terapia láser por el nevus hiperpigmentario. La paciente mostró evolución clínico - quirúrgica favorable con remisión de la sintomatología que motivó su consulta.


Klippel-Trenaunay syndrome is a complex vascular malformation with an incidence of 2 to 3 cases per 100,000 live births. Clinically, it presents a classic triad: port-wine stains, varicose veins of atypical location and bone and soft tissue hypertrophy. We present the case of a 33-year-old female patient, with no pathologic or surgical history of importance, who comes to the clinic for an increase in volume of the right extremity, ipsilateral violaceous spot, in addition to pain and paresthesia. Physical examination revealed longitudinal enlargement of the right lower limb, hyperpigmented nevus on the lateral aspect of the right leg and thigh extending to the ipsilateral buttock and atypical varicose veins. Venous Doppler ultrasound with linear transducer reported incompetence of the greater saphenous vein and supragenicular perforators. Surgical management was performed by saphenectomy, deformity correction and referral to dermatology for laser therapy for hyperpigmented nevus. The patient showed favorable clinical-surgical evolution with remission of the symptomatology that motivated her consultation.


A síndrome de Klippel-Trenaunay é uma malformação vascular complexa com uma incidência de 2 a 3 casos por 100.000 nascidos vivos. Clinicamente, apresenta uma tríade clássica: manchas vinho do porto, veias varicosas de localização atípica e hipertrofia óssea e de tecidos moles. Apresentamos o caso de uma paciente do sexo feminino, 33 anos, sem histórico patológico ou cirúrgico de importância, que consultou por aumento de volume do membro direito, mancha violácea ipsilateral, além de dor e parestesia. O exame físico revelou aumento longitudinal do membro inferior direito, nevo hiperpigmentado na face lateral da perna e coxa direitas, estendendo-se até a nádega ipsilateral e veias varicosas atípicas. Foi realizado ultrassom Doppler venoso com transdutor linear, que relatou incompetência da veia safena magna e das perfurantes suprageniculares. O tratamento cirúrgico foi realizado por meio de safenectomia, correção da deformidade e encaminhamento à dermatologia para terapia a laser para nevo hiperpigmentado. A paciente apresentou uma evolução clínico-cirúrgica favorável com remissão dos sintomas que a levaram à consulta.


Assuntos
Feminino , Adulto
9.
Acta fisiátrica ; 30(1): 69-72, mar. 2023.
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1434957

RESUMO

Não há dúvidas sobre os prejuízos na vida humana, extensivos à família e sociedade como um todo, abrangendo todos os aspectos funcionais das pessoas envolvidas, além do indivíduo, originados dos traumatismos cranioencefálico, agudos e crônicos, externos ou internos: acidentes, atropelamentos, quedas, crimes, acidente vascular cerebral, doenças com neurodegeneração progressiva, resultando em estados demenciais. Ao longo de meio século, houve a introdução contínua de medicamentos, com resultados usualmente contraditórios e frustrantes, exigindo novas tentativas com outras classes farmacológicas. No todo, a limitação se faz sentir na impossibilidade de reversão ou mesmo de mera estabilização dos danos neurológicos, e inocuidade em termos de estimulação da neuroplasticidade. Uma exceção parece ser uma nova abordagem: a estimulação cerebral profunda por pulsos sonoros de baixa frequência (Transcranial Pulse Stimulation, ou TPS). Ainda pouco conhecida, a não ser em alguns centros de tratamento, tem se mostrado ser um acréscimo válido, por complementar os programas multidisciplinares de reabilitação


There is no doubt about the damage to human life, also extended to family and society as a whole, regarding all the functional aspects of those involved, not only the patient itself, which originates from traumatic brain injury, acute or chronic, for external or internal reasons, such as accidents, run overs, falls, crimes, stroke, progressive neurodegenerative diseases that result in dementia states. Over half a century, drugs have been continuously introduced, however their results have constantly been contradictory and frustrating, requiring new attempts with other pharmacological classes. Overall, the limitation is felt in the impossibility of reversing or even merely stabilizing the neurological damage and inefficacy regarding neuroplasticity stimulation. One exception seems to be a new approach, the non-invasive brain stimulation by low-frequency sound pulses (Transcranial Pulse Stimulation, or TPS). Except for some treatment centers, TPS is still unknown, however it has shown to be a valid adjunct in multidisciplinary rehabilitation programs

10.
Femina ; 51(2): 105-113, 20230228. Ilus, Tab
Artigo em Português | LILACS | ID: biblio-1428706

RESUMO

No início do século 20, as altas taxas de mortalidade materna e infantil estimularam o desenvolvimento de um modelo de atendimento pré-natal que mantivesse características parecidas até os dias atuais. Nesse modelo, haveria maior concentração de visitas durante o final do terceiro trimestre de gestação, devido às maiores taxas de complicações nas fases finais da gestação e à dificuldade de prever a ocorrência de resultados adversos durante o primeiro trimestre. Atualmente, a avaliação clínica durante o primeiro trimestre, com auxílio da ultrassonografia e marcadores bioquímicos, pode prever uma série de complicações que acometem a gestação, incluindo cromossomopatias, pré-eclâmpsia, restrição de crescimento fetal, anomalias fetais e trabalho de parto pré-termo.


At the beginning of the 20th century, the high rates of maternal and infant mortality stimulated the development of a model of prenatal care that maintained similar characteristics until the present day. In this model, there would be a greater concentration of visits during the end of the third trimester of pregnancy, due to the higher rates of complications in the final stages of pregnancy and the difficulty in predicting the occurrence of adverse outcomes during the first trimester. Currently, clinical evaluation during the first trimester, with the aid of ultrasound and biochemical markers, can predict a series of complications that affect pregnancy, including chromosomal disorders, preeclampsia, fetal growth restriction, fetal anomalies and preterm labor.


Assuntos
Humanos , Feminino , Gravidez , Pré-Eclâmpsia/diagnóstico por imagem , Ultrassonografia Pré-Natal , Aneuploidia , Trissomia/diagnóstico , Biomarcadores/química , Mortalidade Infantil , Mortalidade Materna , Medição de Risco
11.
Rev. Flum. Odontol. (Online) ; 1(60): 137-146, jan.-abr. 2023. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1411348

RESUMO

Introdução: O aumento da expectativa média de vida leva a população a buscar, com maior frequência, tratamentos estéticos que visem o rejuvenescimento da face e do pescoço. O Ultrassom microfocado (MFU) é descrito como uma opção de tratamento não-invasiva para a flacidez facial e o envelhecimento. Objetivo: Revisar a literatura científica quanto ao uso do MFU no processo de rejuvenescimento facial e correção da flacidez da pele. Metodologia: Trata-se de uma revisão narrativa da literatura, baseada na pesquisa de artigos científicos nas bases de dados PubMed e Biblioteca Virtual em Saúde realizada durante o mês de março de 2022, através da seguinte estratégia de busca: "Microfocused Ultrasound AND Facial Rejuvenation AND Skin Laxity Treatment". Um total de 19 manuscritos foram incluídos em síntese qualitativa. Desenvolvimento: O MFU pode ser aplicado no tecido subcutâneo, produzindo pequenos pontos de coagulação térmica dentro da camada reticular média a profunda da derme e subderme. A aplicação de calor nesses discretos pontos de coagulação térmica faz com que haja neossíntese de colágeno e consequente enrijecimento da pele. Estudos recentes evidenciaramresultados promissores quanto a aplicação do MFU em regiões de sulco nasolabial, linha da mandíbula, sobrancelhas, região infraorbital, palpebra inferior e ligamentos de retenção zigomático-bucais. Considerações finais: O MFU tem se mostrado uma técnica segura, sendo considerado eficaz, não-invasiva, bem tolerada pelos pacientes e viável para a prática clínica médica e odontológica.


Introduction: The increase in average life expectancy leads the population to seek, with greater frequency, aesthetic treatments aimed at rejuvenating the face and neck. Microfocused ultrasound (MFU) is described as a non-invasive treatment option for facial sagging and aging. Objective: To review the scientific literature regarding the use of MFU in the process of facial rejuvenation and correction of sagging skin. Methodology: This is a narrative review of the literature, based on the search for scientific articles in the PubMed and Virtual Health Library databases carried out during the month of March 2022, using the following search strategy: "Microfocused Ultrasound AND Facial Rejuvenation AND Skin Laxity Treatment". A total of 19 manuscripts were included in a qualitative synthesis. Development: MFU can be applied to the subcutaneous tissue, producing small points of thermal coagulation within the middle to deep reticular layer of the dermis and subdermis. The application of heat to these discrete points of thermal coagulation causes collagen neosynthesis and consequent skin tightening. Recent studies have shown promising results regarding the application of MFU in regions of the nasolabial sulcus, jaw line, eyebrows, infraorbital region, lower eyelid and zygomatic-buccal retention ligaments. Final considerations: MFU has been shown to be a safe technique, being considered effective, non-invasive, well tolerated by patients and viable for clinical medical and dental practice.


Assuntos
Rejuvenescimento , Terapia por Ultrassom , Envelhecimento da Pele , Odontologia , Equipamentos para Estética , Face
12.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1536400

RESUMO

Introducción: Las lesiones atípicas de la glándula mamaria afectan a un total de 20 000 mujeres en el mundo. La categorización BI-RADS 4 se considera indefinida y tiene variación considerable a malignidad hasta con cinco años de seguimiento. Objetivo: Establecer la correlación entre los informes BI-RADS 4 y hallazgos histopatológicos en mujeres con diagnóstico de patología atípica de mama que aceden a la consulta de Ginecología y Obstetricia del Hospital Provincial General Docente de Riobamba, Ecuador. Método: Se realizó un estudio de tipo analítico correlacional, retrospectivo, no experimental, de corte transversal en el periodo enero-diciembre de 2021, en 78 pacientes de 20 a 70 años. Los datos fueron tomados de las historias clínicas. Para la validez de pruebas se usó pruebas estadísticas tipo Ji cuadrado de correlación con intervalos de confianza del 95 % e índice de error del 5 %. Resultados: El principal factor de riesgo observado fue la edad ≥40 años (26,92 %), seguido de: deformidad mamaria (20,51 %), y recurrencia de nódulos (15,38 %). En relación a las subcategorías del informe BI-RADS 4, se observó que el tipo C fue la de mayor prevalencia con 39 casos (50 %). Predominó la hiperplasia ductal con el 44,87 % y la fue de un 95,83 % con una especificidad del 70 %. Hubo una significación asintónica de 0,001 entre BI-RADS 4 y resultados histopatológicos. Conclusiones: Las lesiones subcategorizadas como BI-RADS 4C tienen mayor probabilidad de malignizar debido a que se asocian principalmente a hiperplasia ductal, siendo esta el principal cáncer mamario en mujeres mayores de 40 años.


Introduction: Atypical lesions of the mammary gland affect a total of 20,000 women worldwide. The BI-RADS 4 categorization is considered indefinite and has considerable variation to malignancy with up to five years of follow-up. Objective: To establish the correlation between BI-RADS 4 reports and histopathological findings in women with a diagnosis of atypical breast pathology who attend the Gynecology and Obstetrics consultation of the Hospital Provincial General Docente de Riobamba, Ecuador. Method: A correlational, retrospective, non-experimental, cross-sectional analytical study was carried out in the period January-December 2021, in 78 patients aged 20 to 70 years. The data were taken from the medical records. For the validity of the tests, Chi-square correlation statistical tests were used with 95% confidence intervals and an error rate of 5%. Results: The main risk factor observed was age ≥40 years (26.92%), followed by: breast deformity (20.51%), and recurrence of nodules (15.38%). In relation to the subcategories of the BI-RADS 4 report, it was observed that type C was the most prevalent with 39 cases (50%). Ductal hyperplasia predominated with 44.87% and was 95.83% with a specificity of 70%. There was an asymptomatic significance of 0.001 between BI-RADS 4 and histopathological results. Conclusions: Lesions subcategorized as BI-RADS 4C are more likely to become malignant because they are mainly associated with ductal hyperplasia, this being the main breast cancer in women over 40 years of age.


Introdução: Lesões atípicas da glândula mamária afetam um total de 20.000 mulheres em todo o mundo. A categorização BI-RADS 4 é considerada indefinida e apresenta variação considerável para malignidade com até cinco anos de acompanhamento. Objetivo: Estabelecer a correlação entre os laudos BI-RADS 4 e os achados histopatológicos em mulheres com diagnóstico de patologia mamária atípica que atendem na consulta de Ginecologia e Obstetrícia do Hospital Provincial General Docente de Riobamba, Equador. Método: Estudo correlacional, retrospectivo, não experimental, transversal, analítico, foi realizado no período de janeiro a dezembro de 2021, em 78 pacientes com idade entre 20 e 70 anos. Os dados foram retirados dos prontuários médicos. Para a validade dos testes foram utilizados testes estatísticos de correlação qui-quadrado com intervalos de confiança de 95% e taxa de erro de 5%. Resultados: O principal fator de risco observado foi idade ≥40 anos (26,92%), seguido de: deformidade mamária (20,51%) e recorrência de nódulos (15,38%). Em relação às subcategorias do relatório BI-RADS 4, observou-se que o tipo C foi o mais prevalente com 39 casos (50%). A hiperplasia ductal predominou com 44,87% e foi de 95,83% com especificidade de 70%. Houve significância assintomática de 0,001 entre o BI-RADS 4 e os resultados histopatológicos. Conclusões: Lesões subcategorizadas como BI-RADS 4C têm maior probabilidade de se tornarem malignas porque estão associadas principalmente à hiperplasia ductal, sendo este o principal câncer de mama em mulheres com mais de 40 anos.

13.
Rev. Esc. Enferm. USP ; 57: e20230132, 2023. tab
Artigo em Inglês, Português | LILACS, BDENF - Enfermagem | ID: biblio-1521557

RESUMO

ABSTRACT Objective: To analyze the direct costs of materials, medicines/solutions and healthcare professionals required to treat men with prostate cancer using High Intensity Focused Ultrasound. Method: Quantitative, exploratory-descriptive research, single case study type. Data were collected from electronic medical records/printed documentation from the Operating Room of a public teaching and research hospital. Health professionals estimated the respective time spent on activities in the following stages: "Before anesthetic induction", "Before performing thermal ablation", "During thermal ablation" and "After performing thermal ablation". Costs were calculated by multiplying the (estimated) time spent by the unit cost of direct labor, adding to the measured cost of materials, medicines/solutions. Results: The measured costs with materials corresponded to US$851.58 (SD = 2.17), with medicines/solutions to US$72.13 (SD = 25.84), and estimated personnel costs to US$196.03, totaling US$1119.74/procedure. Conclusion: The economic results obtained may support hospital managers in the decision-making process regarding the adoption of the High Intensity Focused Ultrasound for the treatment of prostate cancer.


RESUMEN Objetivo: Analizar los costos directos de materiales, medicamentos/soluciones y profesionales de la salud necesarios para tratar a hombres con cáncer de próstata a través de High Intensity Focused Ultrasound. Método: Investigación cuantitativa, exploratoria-descriptiva, tipo estudio de caso único. Los datos se obtuvieron de registros médicos electrónicos/documentación impresa del Centro Quirúrgico de un hospital público de enseñanza e investigación. Los profesionales de la salud estimaron el tiempo respectivo dedicado a las actividades en las siguientes etapas: "Antes de la inducción anestésica", "Antes de realizar la ablación térmica", "Durante la realización de la ablación térmica" y "Después de realizar la ablación térmica". Los costos se calcularon multiplicando el tiempo (estimado) invertido por el costo unitario de la mano de obra directa, sumándolo al costo medido de materiales, medicamentos/soluciones. Resultados: Los costos medidos con materiales correspondieron a US$851,58 (DE = 2,17), con medicamentos/soluciones a US$72,13 (DE = 25,84) y los costos de personal estimados a US$196,03, totalizando US$1119,74/procedimiento. Conclusión: Los resultados económicos obtenidos podrán apoyar a los gestores hospitalarios en el proceso de toma de decisiones respecto a la adopción del High Intensity Focused Ultrasound para el tratamiento del cáncer de próstata.


RESUMO Objetivo: Analisar os custos diretos com materiais, medicamentos/soluções e profissionais de saúde requeridos à realização do tratamento de homens com câncer de próstata via High Intensity Focused Ultrasound. Método: Pesquisa quantitativa, exploratória-descritiva, do tipo estudo de caso único. Coletaram-se os dados em prontuários eletrônicos/documentações impressas do Centro Cirúrgico de um hospital público de ensino e pesquisa. Profissionais de saúde estimaram os respectivos tempos despendidos em atividades constantes das etapas: "Antes da indução anestésica", "Antes da execução da termoablação", "Durante a execução da termoablação" e "Após a execução da termoablação". Calcularam-se os custos multiplicando-se o tempo (estimado) despendido pelo custo unitário da mão de obra direta, somando-se ao custo mensurado dos materiais, medicamentos/soluções. Resultados: Os custos mensurados com materiais corresponderam a US$851,58 (DP = 2,17), com medicamentos/soluções a US$72,13 (DP = 25,84) e os custos estimados com pessoal a US$196,03, totalizando US$1119,74/procedimento. Conclusão: Os resultados econômicos obtidos poderão subsidiar os gestores hospitalares no processo decisório quanto à adoção do High Intensity Focused Ultrasound para o tratamento do câncer de próstata.


Assuntos
Humanos , Masculino , Neoplasias da Próstata , Custos e Análise de Custo , Custos Diretos de Serviços , Ultrassom Focalizado Transretal de Alta Intensidade , Usos Terapêuticos , Assistência Hospitalar
14.
Arq. neuropsiquiatr ; 81(10): 861-867, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1527870

RESUMO

Abstract Background Intracerebral hemorrhage (ICH) is a deadly disease and increased intracranial pressure (ICP) is associated with worse outcomes in this context. Objective We evaluated whether dilated optic nerve sheath diameter (ONSD) depicted by optic nerve ultrasound (ONUS) at hospital admission has prognostic value as a predictor of mortality at 90 days. Methods Prospective multicenter study of acute supratentorial primary ICH patients consecutively recruited from two tertiary stroke centers. Optic nerve ultrasound and cranial computed tomography (CT) scans were performed at hospital admission and blindly reviewed. The primary outcome was mortality at 90-days. Multivariate logistic regression, ROC curve, and C-statistics were used to identify independent predictors of mortality. Results Between July 2014 and July 2016, 57 patients were evaluated. Among those, 13 were excluded and 44 were recruited into the trial. Their mean age was 62.3 ± 13.1 years and 12 (27.3%) were female. On univariate analysis, ICH volume on cranial CT scan, ICH ipsilateral ONSD, Glasgow coma scale, National Institute of Health Stroke Scale (NIHSS) and glucose on admission, and also diabetes mellitus and current nonsmoking were predictors of mortality. After multivariate analysis, ipsilateral ONSD (odds ratio [OR]: 6.24; 95% confidence interval [CI]: 1.18-33.01; p = 0.03) was an independent predictor of mortality, even after adjustment for other relevant prognostic factors. The best ipsilateral ONSD cutoff was 5.6mm (sensitivity 72% and specificity 83%) with an AUC of 0.71 (p = 0.02) for predicting mortality at 90 days. Conclusion Optic nerve ultrasound is a noninvasive, bedside, low-cost technique that can be used to identify increased ICP in acute supratentorial primary ICH patients. Among these patients, dilated ONSD is an independent predictor of mortality at 90 days.


Resumo Antecedentes A hemorragia intraparenquimatosa (HIP) aguda apresenta elevada morbimortalidade e a presença de hipertensão intracraniana (HIC) confere um pior prognóstico. Objetivo Avaliamos se a dilatação do diâmetro da bainha do nervo óptico (DBNO) através do ultrassom do nervo óptico (USNO) na admissão hospitalar seria preditora de mortalidade. Métodos Estudo multicêntrico e prospectivo de pacientes consecutivos com HIP supratentorial primária aguda admitidos em dois centros terciários. Ultrassom do nervo óptico e tomografia computadorizada (TC) de crânio foram realizados na admissão e revisados de forma cega. O desfecho primário do estudo foi a mortalidade em 3 meses. Análises de regressão logística, curva de característica de operação do receptor (ROC, na sigla em inglês) e estatística-C foram utilizadas para identificação dos preditores independentes de mortalidade. Resultados Entre julho de 2014 e julho de 2016, 44 pacientes foram incluídos. A idade média foi 62,3 (±13,1) anos e 12 (27,3%) eram mulheres. Na análise univariada, o volume da HIP na TC de crânio, DBNO ipsilateral à HIP, glicemia, escala de coma de Glasgow (ECG) e NIHSS na admissão hospitalar, e também diabetes mellitus e não-tabagista foram preditores de mortalidade. Após análise multivariada, o DBNO ipsilateral à HIP permaneceu como preditor independente de mortalidade (odds ratio [OR]: 6,24; intervalo de confiança [IC] de 95%: 1,18-33,01; p = 0,03). O melhor ponto de corte do DBNO ipsilateral como preditor de mortalidade em 3 meses foi 5,6mm (sensibilidade 72% e especificidade 83%) e área sob a curva (AUC, na sigla em inglês) 0,71 (p = 0,02). Conclusão O USNO é um método não-invasivo, beira-leito, de baixo custo, que pode ser empregado para estimar a presença de HIC em pacientes com HIP supratentorial primária aguda. A presença de DBNO dilatada é um preditor independente de mortalidade em 3 meses nesses pacientes.

15.
Braz. J. Vet. Res. Anim. Sci. (Online) ; 60: e194905, 2023. ilus, graf, tab
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1518167

RESUMO

Gallbladder mucocele is characterized by hyperplasia of the gallbladder epithelium, increased mucus production, accumulation, and densification of the bile content, which can lead to biliary obstruction, necrosis, and rupture of the gallbladder wall. Its finding may be accidental or related to symptoms. A retrospective study (2016-2019) was carried out based on abdominal ultrasound examinations in dogs, correlating aspects of the gallbladder and biliary system in the mucocele with existing comorbidities. Thirty dogs diagnosed with biliary mucocele were evaluated, of which 46.66% had the disease at an early stage, and 53.33% showed a more advanced stage. Of these, 66.66% were related to endocrinopathies and hyperadrenocorticism. Signs of extrahepatic bile duct obstruction and biliary peritonitis were observed in two animals. Due to their potential risk of complications, follow-up ultrasound assessments are indicated in cases that opt for clinical treatment, not excluding the need for surgical intervention.(AU)


A mucocele biliar caracteriza-se pela hiperplasia do epitélio da vesícula biliar, aumento da produção de muco, acúmulo e densificação do conteúdo biliar, podendo levar à obstrução, necrose e ruptura da parede da vesícula biliar. Seu achado pode ser acidental ou estar relacionado à sintomatologia. Foi realizado um estudo retrospectivo (2016-2019) a partir de exames ultrassonográficos abdominais em cães, correlacionando os aspectos da vesícula biliar na mucocele, com comorbidades existentes. Foram avaliados 30 cães com diagnóstico de mucocele biliar, dos quais 46,66% apresentaram a doença em estágio inicial e 53,33% demonstraram estágio mais avançado. Destes, 66,66% tinham endocrinopatias, principalmente hiperadrenocorticismo. Sinais de obstrução de vias biliares extra-hepáticas e peritonite biliar foram observados em dois animais. Por seu potencial risco de complicação, avaliações ultrassonográficas de seguimento são indicadas nos casos de tratamento clínico, não se descartando a necessidade de intervenção cirúrgica.(AU)


Assuntos
Animais , Cães , Doenças do Sistema Endócrino/diagnóstico por imagem , Mucocele/diagnóstico por imagem , Ductos Biliares , Cães
16.
Rev. bras. ginecol. obstet ; 45(8): 480-488, 2023.
Artigo em Inglês | LILACS | ID: biblio-1515058

RESUMO

Abstract Objective To present the update of the recommendations of the Brazilian College of Radiology and Diagnostic Imaging, the Brazilian Society of Mastology and the Brazilian Federation of Associations of Gynecology and Obstetrics for breast cancer screening in Brazil. Methods Scientific evidence published in Medline, EMBASE, Cochrane Library, EBSCO, CINAHL and Lilacs databases between January 2012 and July 2022 was searched. Recommendations were based on this evidence by consensus of the expert committee of the three entities. Recommendations Annual mammography screening is recommended for women at usual risk aged 40-74 years. Above 75 years, it should be reserved for those with a life expectancy greater than seven years. Women at higher than usual risk, including those with dense breasts, with a personal history of atypical lobular hyperplasia, classic lobular carcinoma in situ, atypical ductal hyperplasia, treatment for breast cancer or chest irradiation before age 30, or even, carriers of a genetic mutation or with a strong family history, benefit from complementary screening, and should be considered individually. Tomosynthesis is a form of mammography and should be considered in screening whenever accessible and available.


Resumo Objetivo Apresentar a atualização das recomendações do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem da Sociedade Brasileira de Mastologia e da Federação Brasileira das Associações de Ginecologia e Obstetrícia para o rastreamento do câncer de mama no Brasil. Métodos Foram pesquisadas evidências científicas publicadas nas bases de dados Medline EMBASE Biblioteca Cochrane EBSCO CINAHL e Lilacs entre janeiro de 2012 e julho de 2022. As recomendações foram baseadas nessas evidências por consenso do comitê de especialistas das três entidades. Recomendações A mamografia anual é recomendada para mulheres com risco habitual entre 40 e 74 anos. Acima de 75 anos deve ser reservado para aqueles com expectativa de vida superior a sete anos. Mulheres com risco maior do que o normal incluindo aquelas com mamas densas com história pessoal de hiperplasia lobular atípica carcinoma lobular in situ clássico hiperplasia ductal atípica tratamento para câncer de mama ou irradiação de tórax antes dos 30 anos ou ainda portadoras de doença genética mutação ou com forte histórico familiar beneficiam-se de triagem complementar e devem ser considerados individualmente. A tomossíntese é uma forma de mamografia e deve ser considerada na triagem sempre que acessível e disponível.


Assuntos
Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética , Mamografia , Programas de Rastreamento
17.
Braz. j. biol ; 83: 1-5, 2023. ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1468893

RESUMO

Morphophysiological species researches are fundamental, and diagnostic imaging is an excellent technique, already used in wild animals, with great application, not invasive and provide real-time information of each body. Amazonian manatees are on the list of endangered animals classified in the vulnerable category and knowledge of the normal pattern of ultrasound anatomy of organs and tissues is important for the maintenance and well-being of captive specimens contributing to reintroduction actions. The objective of the study was to standardize the examination technique and describe the ultrasound findings of the liver, gallbladder, stomach, urinary bladder and the subcutaneous tissue of the abdominal region in Trichechus inunguis, in order to contribute with the anatomical and sonographic knowledge and assist in the diagnosis and prognosis diseases. The study used 18 animals to describe the normal sonographic anatomy in the abdominal cavity of the Amazonian manatee. During abdominal scan, it was possible to visualize the features of the liver, gallbladder, stomach, urinary bladder obtained satisfactory results in this study. Therefore, other structures were not primarily identified by the reduced time, lots of fat and gases in intestines of animals.


Pesquisas morfofisiológicas em espécies selvagens são fundamentais, e o diagnóstico por imagem é uma excelente técnica, já usada e com grande aplicação, não invasiva e que fornece informações em tempo real de cada órgão. Peixes-boi-amazônico encontram-se na lista de animais ameaçados de extinção classificados na categoria vulnerável e o conhecimento do padrão normal da anatomia ultrassonográfica de órgãos e tecidos é importante para a manutenção e bem-estar de espécimes em cativeiro contribuindo para ações de reintrodução. O objetivo deste estudo foi padronizar a técnica de exame e descrever os achados ultrassonográficos do fígado, vesícula biliar, estômago, vesícula urinária e o tecido subcutâneo da região abdominal em Trichechus inunguis, de modo a contribuir com o conhecimento anátomo-sonográfico e auxiliar no diagnóstico e prognóstico de doenças. O estudo utilizou 18 animais para descrever a anatomia ultrassonográfica normal na cavidade abdominal de peixe-boi amazônico. Durante a varredura abdominal foi possível visualizar as características dos órgãos obtendo resultados satisfatórios neste estudo, concluindo ser uma técnica eficiente para avaliação de determinados órgãos abdominais em peixe-boi amazônico. Entretanto, outras estruturas não foram identificadas principalmente pelo tempo reduzido, muita gordura e gases nos intestinos dos animais.


Assuntos
Animais , Anatomia Transversal , Bexiga Urinária/anatomia & histologia , Estômago/anatomia & histologia , Fígado/anatomia & histologia , Tela Subcutânea/anatomia & histologia , Trichechus , Ultrassonografia/métodos , Ultrassonografia/veterinária , Vesícula Biliar/anatomia & histologia
18.
Braz. j. biol ; 832023.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469109

RESUMO

Abstract Morphophysiological species researches are fundamental, and diagnostic imaging is an excellent technique, already used in wild animals, with great application, not invasive and provide real-time information of each body. Amazonian manatees are on the list of endangered animals classified in the vulnerable category and knowledge of the normal pattern of ultrasound anatomy of organs and tissues is important for the maintenance and well-being of captive specimens contributing to reintroduction actions. The objective of the study was to standardize the examination technique and describe the ultrasound findings of the liver, gallbladder, stomach, urinary bladder and the subcutaneous tissue of the abdominal region in Trichechus inunguis, in order to contribute with the anatomical and sonographic knowledge and assist in the diagnosis and prognosis diseases. The study used 18 animals to describe the normal sonographic anatomy in the abdominal cavity of the Amazonian manatee. During abdominal scan, it was possible to visualize the features of the liver, gallbladder, stomach, urinary bladder obtained satisfactory results in this study. Therefore, other structures were not primarily identified by the reduced time, lots of fat and gases in intestines of animals.


Resumo Pesquisas morfofisiológicas em espécies selvagens são fundamentais, e o diagnóstico por imagem é uma excelente técnica, já usada e com grande aplicação, não invasiva e que fornece informações em tempo real de cada órgão. Peixes-boi-amazônico encontram-se na lista de animais ameaçados de extinção classificados na categoria vulnerável e o conhecimento do padrão normal da anatomia ultrassonográfica de órgãos e tecidos é importante para a manutenção e bem-estar de espécimes em cativeiro contribuindo para ações de reintrodução. O objetivo deste estudo foi padronizar a técnica de exame e descrever os achados ultrassonográficos do fígado, vesícula biliar, estômago, vesícula urinária e o tecido subcutâneo da região abdominal em Trichechus inunguis, de modo a contribuir com o conhecimento anátomo-sonográfico e auxiliar no diagnóstico e prognóstico de doenças. O estudo utilizou 18 animais para descrever a anatomia ultrassonográfica normal na cavidade abdominal de peixe-boi amazônico. Durante a varredura abdominal foi possível visualizar as características dos órgãos obtendo resultados satisfatórios neste estudo, concluindo ser uma técnica eficiente para avaliação de determinados órgãos abdominais em peixe-boi amazônico. Entretanto, outras estruturas não foram identificadas principalmente pelo tempo reduzido, muita gordura e gases nos intestinos dos animais

19.
Dental press j. orthod. (Impr.) ; 28(2): e2321252, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1439991

RESUMO

ABSTRACT Objective: The aim of this study was to evaluate the volumetric root resorption in maxillary incisors following clear aligner therapy (CAT) with low-intensity pulsed ultrasound (LIPUS), and compare the results to CAT alone. Material and Methods: This retrospective study evaluated pretreatment (T0) and post-treatment (T1) cone-beam computed tomography imaging of 42 adult patients. Twenty-one patients (14 females, 7 males, mean age= 38.1±12.96 years) were treated using CAT with LIPUS device, whereas the other twenty-one matching controls patients (15 females, 6 males, mean age= 35.6±11.7 years) were treated using CAT alone. Images were analyzed and a segmentation protocol was applied on the maxillary incisors. Each segmented tooth volume was exported as a surface mesh in the Visualization Toolkit (VTK) file format. The VTK files for all maxillary incisors were coded and corresponding teeth volumes from T0 and T1 were superimposed. Clipping the crown of each tooth was done, then measurements of root volumes and differences between groups were performed. Changes in root volumes were assessed (p<0.05). Results: Root loss was evident in all teeth in both groups, but was significantly increased in all maxillary incisors of the control group (p<0.001) and in upper left central incisor of LIPUS group (p=0.009). When both groups were compared, there was statistically significant minimal volumetric root loss in LIPUS group (3.50-7.32 mm3), when compared to control group (11.48-12.95 mm3) (p<0.05). Conclusion: LIPUS group showed less volumetric root resorption compared to control group during the studied treatment time using clear aligners.


RESUMO Objetivo: O objetivo deste estudo foi avaliar volumetricamente a reabsorção radicular em incisivos superiores após tratamento com alinhadores transparentes (CAT) com e sem uso adjuvante de ultrassom de baixa intensidade (LIPUS). Material e Métodos: Esse estudo retrospectivo avaliou imagens de tomografia computadorizada de feixe cônico pré-tratamento (T0) e pós-tratamento (T1) de 42 pacientes adultos: 21 pacientes (14 mulheres, 7 homens, idade média= 38,1±12,96 anos) foram tratados com CAT e LIPUS, enquanto os outros 21 pacientes controles correspondentes (15 mulheres, 6 homens, idade média= 35,6±11,7 anos) foram tratados apenas com CAT. As imagens foram analisadas e foi aplicado um protocolo de segmentação dos incisivos superiores. Os volumes de cada dente segmentado foram exportados como malhas de superfície, em arquivos no formato Visualization Toolkit (VTK). Os arquivos VTK de todos os incisivos superiores foram codificados e foram sobrepostos os volumes dos dentes correspondentes a T0 e T1. Foi realizada a clipagem da coroa de cada dente e, em seguida, foram realizadas medições dos volumes radiculares e comparadas as diferenças entre os grupos, avaliando-se as alterações nos volumes de raízes (p<0,05). Resultados: A perda radicular foi evidente em todos os dentes em ambos os grupos, mas foi significativamente maior em todos os incisivos superiores do grupo controle (p<0,001) e no incisivo central superior esquerdo do grupo LIPUS (p=0,009). Quando ambos os grupos foram comparados, houve perda volumétrica mínima estatisticamente significativa no grupo LIPUS (3,50-7,32 mm3), em comparação ao grupo controle (11,48-12,95 mm3) (p<0,05). Conclusão: O grupo LIPUS apresentou menor volume de reabsorção radicular, em comparação ao grupo controle, durante o tempo de tratamento estudado usando alinhadores transparentes.

20.
Rev. bras. cineantropom. desempenho hum ; 25: e93936, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1507828

RESUMO

Abstract Due to its low cost and operational simplicity, ultrasound has been used to monitor muscle thickness in laboratory environments, rehabilitation clinics, and sports clubs. However, it is necessary to determine the measurement's quality to infer whether the possible changes observed are derived from the treatment or the measurement error. Therefore, we performed a systematic review to determine the validity, reliability, and measurement error of quadriceps femoris muscle thickness obtained by ultrasound in healthy adults. A search was conducted in the Pubmed, Scopus, and Web of Science databases until April 2022. The study selection process was carried out by two independent researchers, with the presence of a third researcher in case of disagreements. Twenty-six studies were eligible for the review, being 4 of validity, 4 of reliability only, and 18 of reliability and measurement error. The intraclass correlation coefficient ranged from 0.60 to 0.99 in validity studies and from 0.44 to 0.99 in reliability studies. The typical error of measurement ranged from 0.01 to 0.47 cm, and the coefficient of variation was from 0.5 to 17.9%. Four studies received "very good" classification in all the risk of bias analysis criteria. Therefore, it is concluded that the quadriceps femoris muscle thickness obtained by ultrasound was shown to be valid, reliable, and to have low measurement errors in healthy adults. The weighted average of the relative error was 6.5%, less than typical increases in resistance training studies. The raters' experience and methodological care for repeated measurements were necessary to observe low measurement errors.


Resumo Devido ao baixo custo e simplicidade operacional, a ultrassonografia tem sido utilizada para monitorar a espessura muscular em ambientes laboratoriais, clínicas de reabilitação e clubes desportivos. Porém, é necessário determinar a qualidade da medida para inferir se as possíveis modificações observadas são decorrentes do tratamento ou do erro da medida. Portanto, realizamos uma revisão sistemática para determinar a validade, confiabilidade e erro da medida da espessura muscular do quadríceps femoral obtida pela ultrassonografia em adultos saudáveis. Foi realizada busca nas bases de dados Pubmed, Scopus e Web of Science até abril de 2022. O processo de seleção dos estudos foi realizado por dois pesquisadores independentes, com a presença de um terceiro pesquisador em caso de divergências. Vinte e seis estudos foram elegíveis para a revisão, sendo 4 de validade, 4 apenas de confiabilidade e 18 de confiabilidade e erro de medida. O coeficiente de correlação intraclasse variou de 0,60 a 0,99 em estudos de validade e 0,44 a 0,99 em estudos de confiabilidade. O erro típico da medida variou de 0,01 a 0,47 cm e o coeficiente de variação foi de 0,5 a 17,9%. Quatro estudos receberam classificação "muito bom" em todos os critérios na análise de risco de viés. Portanto, concluiu-se que a espessura muscular do quadríceps femoral obtida pela ultrassonografia se mostrou válida, confiável e com baixos erros de medida em adultos saudáveis. A média ponderada do erro relativo foi de 6,5%, menor do que os aumentos típicos em estudos de treinamento resistido. A experiência dos avaliadores e o cuidado metodológico com as medidas repetidas foram necessários para observar baixos erros de medida.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA